Contamination of standard examination glove packaging-Evaluation of a Non-Sterile Glove Dispensing System SafeDon – Study Results
Streszczenie
Szpitale, gabinety dentystyczne oraz laboratoria to miejsca, w których u¿ywa siê niesterylnych rêkawic jednorazowych zapakowanych w kartonowe pude³ka. Podczas wyjmowania rêkawic mo¿e doj¶æ do przeniesienia mikroorganizmów z d³oni u¿ytkownika na rêkawice, a nastêpnie na pacjentów. Nowatorski system pakowania rêkawic typu Safedon redukuje ryzyko kontaminacji. Wykaza³ to dr Uyen Nguyen, który przeprowadzi³ porównawcze badanie poziomu ska¿enia rêkawic pobieranych z opakowañ nowego systemu i z tradycyjnych pude³ek. Rêkawice by³y u¿ywane przez osoby pracuj±ce w ró¿nych instytucjach komercyjnych i placówkach ochrony zdrowia. Próbki pobierano z ka¿dej placówki raz w tygodniu przez sze¶æ tygodni, nastêpnie okre¶lano poziom obci±¿enia ich bakteriami oraz ple¶ni±. Rêkawice z podajników Safedon okaza³y siê mniej ska¿one ni¿ rêkawice z tradycyjnych opakowañ. We wszystkich placówkach stwierdzono ska¿enie rêkawic w podajnikach Safedon o 92,5% mniejsze, a ple¶ni± – o 88,6% ni¿ ska¿enie rêkawic w opakowaniach standardowych. Powy¿sze dane sugeruj±, ¿e opakowania typu Safedon skutecznie ograniczaj± ska¿enia niewykorzystanych rêkawic, co mo¿e zapobiegaæ rozprzestrzenianiu siê zaka¿eñ szpitalnych.
Summary
Hospitals, dental offices, and laboratories are some of the places that use non-sterile gloves packaged in cardboard boxes. Removing gloves from the boxes could potentially result in the transfer of organisms from the user’s hand to the gloves, which could then be transferred to patients. A new glove packing system was designed by Safedon to reduce the risk of glove contamination. Traditional “tissue box” glove boxes and Safedon were dispensed and used by the workers in various commercial and healthcare settings to compare bioburden on the gloves. Author of the study is dr Uyen Nguyen. Samples were taken at each site on a weekly basis over a 6-week period to determine the level of bacteria and mould bioburden. Gloves dispensed from the Safedon packaging system were found to be less contaminated than traditional „tissue box” dispensing systems. Comparing all the sites, Safedon gloves had > 92.5% less bacterial contamination and 88.6% less mould contamination compared to tissue box gloves. These data suggest Safedon gloves are effective at reducing contamination of unused gloves, thereby limiting the spread of pathogens to patients and the environment.
S³owa kluczowe/Key words
rêkawice diagnostyczne ➧ standardowe opakowania rêkawic diagnostycznych ➧ kontaminacja ➧ zaka¿enia szpitalne ➧ Safedon
examination Gloves ➧ standard examination gloves packaging ➧ contamination ➧ nosocomial infections ➧ Safedon
|